Fault Calculation - Symmetrical Components

By Steven McFadyen on 3/27/2013 12:52 PM

For unbalance conditions the calculation of fault currents is more complex. One method of dealing with this is symmetrical components. Using symmetrical components, the unbalance system is broken dow... read more..


Hazardous Areas – IEC and NEC/CEC Comparison

By Steven McFadyen on 3/9/2012 11:39 AM

Depending where in the world you work, you are likely following one of two standards

  • International Electrotechnical Commissio... read more..


Maxwell's Equations - Gauss's Electric Field Law

By Steven McFadyen on 9/4/2013 3:47 PM

Gauss's Electrical law defines the relation between charge ("Positive" & "Negative") and electric field.  The law was initially formulated by Carl Friedrich Gauss in 1835.

In Gauss'... read more..


Introduction to Current Transformers

By Steven McFadyen on 2/8/2013 11:17 AM

Current transformers (CTs) are used to convert high level currents to a sma... read more..


Dielectric loss in cables

By Steven McFadyen on 11/12/2013 5:19 AM

Dielectrics (insulating materials for example) when subjected to a varying electric field, will have some energy loss.   The varying electric field causes small realignment of weakly bonded mo... read more..


What happened to the cable notes?

By Steven McFadyen on 8/5/2017 3:00 PM

If you are wondering what happe... read more..


Cable Sizing Software

By Steven McFadyen on 10/21/2016 12:31 PM

When sizing cables nearly, everyone uses some form of software. This ranges from homespun spreadsheets to complex network analyses software. Each has its advantages and disadvantages. read more..


Three Phase Current - Simple Calculation

By Steven McFadyen on 3/1/2009 11:47 AM

The calculation of current in a three phase system has been brought up on our site feedback and is a discussion I seem to get involved in every now and again. While some colleagues prefer to remember... read more..


Motor Efficiency Classification

By Steven McFadyen on 3/28/2012 2:05 PM

Electric motors are one of the most widely used items of electrical equipment. Improving motor efficiency benefits include, reduced power demand, lower operating costs and reduced environment impact.... read more..


Maximum Demand for Buildings

By Steven McFadyen on 6/16/2010 5:42 PM

Estimating maximum demand is a topic frequently discussed. Working out how much power to allow for a building can be very subjective . Allowing too much power results in additional equipment, increased ... read more..


Cable Sheath and Armour Loss

By Steven McFadyen on 10/13/2013 11:44 PM

When sizing cables, the heat generated  by losses within any sheath or armour need to be evaluated. When significant, it becomes a factor to be considered in the sizing of cables.

This ... read more..


Batteries

By Steven McFadyen on 4/8/2012 1:38 PM

A battery consists of one or more cells, each of which use stored chemical energy to produce electrical energy, There are many types of cells and these are combined in a multitude of ways to produce ... read more..


Pages: Prev1234567...16NextReturn Top


Voltage Levels to IEC 60038

The standard aims to consolidate AC and traction voltages within the industry and defines the following bands: band 1 - A.C. systems 100 V to 1...

Write your best report

Years ago I was told that you should always try to write the best report you can.  Many years later I still think on this as one of the better pieces of...

IEEE Winds of Change

IEEE TV has a part series of videos on wind power and it's implication. For a really good overview to the technologies and issues around wind power, these...

Nikola Tesla

Nikola Tesla was born exactly at midnight on July 10, 1856 in the tiny village of Smiljan, Lika in Croatia. In his late teens, Tesla left the village to...

Bows and Arrows

It starts with me reading one of the Horrible History books with my son (Groovy Greeks). Arrows were mentioned which lead to the discussion of the bodkin...

Lead us, Warleader

Delum, who had watched all in silence, his face empty of expression, now spoke in turn. ' "Lead us, Warleader, into glory."' Reading is something I do...

What is an Open Delta Transformer

In three phase systems, the use of transformers with three windings (or legs) per side is common.  These three windings are often connected in delta or...

Electromechanical Relays

Electromechanical relays have been the traditional backbone of electrical protection systems.  While over recent years these have been replaced by microprocessor...

Understanding Motor Duty Rating

One of the comments on my Motor Starting Series was asking for something on duty cycles. Here it is. As a purchaser of a motor, you have responsibility...

Are We Losing Professional Integrity

I have been thinking recently that there appears to be less professional integrity around than when I first started my career in electrical engineering...

Have some knowledge to share

If you have some expert knowledge or experience, why not consider sharing this with our community.  

By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.

To get started and understand our policy, you can read our How to Write an Electrical Note