Some colleagues had an issue earlier in the week on sizing conduits to be cast in concrete for some power cables . It became clear that none of us had a clear idea on an approved method. In the end w... read more..
Request to look at induction motor starting time have come up a few times on the site. Hopefully in this post, I give you guys some idea on how to calculate this. Failing that, hopefully at least som... read more..
A quick post in connection with an email question:
Live Tank - the circuit breaker the switching unit is located in an insulator bushing which is live at line voltage (or some voltage above g... read more..
The correct sizing of current transformers is required to ensure satisfactory operation of measuring instruments and protection relays. Several methods exist to size current transformers. This note will... read more..
If you want to check a circuit is dead (not live), you should always use the three point method. First check a known live circuit, then check the dead circuit and finally recheck the live circuit. Carry... read more..
Alternating current (a.c.) is the backbone of modern electrical power distribution. In this article I’ll be pulling some of the more important concepts...
GE have put together a time-lapse video shown flight take-off and landings at some airports. An interesting view:
Just added a page to the tools, which will allow you to calculate the synchronous speed, slip and rated torque for an induction motor. Not a particularly...
IEC 62305 'Protection against lightning' requires a risk assessment be carried out to determine the characteristics of any lightning protection system...
Insulation on a motor prevents interconnection of windings and the winding to earth. When looking at motors, it is important to understand how the insulation...
‘Kept looking at a card, y’see? Kept looking at it. Welcome back Bottle. Gods below welcome home. The Crippled God A Tale of the Malazan Book of the...
A quick post in connection with an email question: Live Tank - the circuit breaker the switching unit is located in an insulator bushing which is live...
Power factor is the ratio between the real power (P in kW) and apparent power (S in kVA) drawn by an electrical load. The reactive power (Q in kVAr)...
Our question and answer system while letting you do exactly what it says, is much more. It is a dynamic user driven system, where our users not only ask...
Within Europe the European Committee for Electrotechnical Standardization (CENELEC) has standardised the both the designation and colour of cables. ...
If you have some expert knowledge or experience, why not consider sharing this with our community.
By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.
To get started and understand our policy, you can read our How to Write an Electrical Note.