Fault Calculation - Symmetrical Components

By Steven McFadyen on 3/27/2013 12:52 PM

For unbalance conditions the calculation of fault currents is more complex. One method of dealing with this is symmetrical components. Using symmetrical components, the unbalance system is broken dow... read more..


Hazardous Areas – IEC and NEC/CEC Comparison

By Steven McFadyen on 3/9/2012 11:39 AM

Depending where in the world you work, you are likely following one of two standards

  • International Electrotechnical Commissio... read more..


Maxwell's Equations - Gauss's Electric Field Law

By Steven McFadyen on 9/4/2013 3:47 PM

Gauss's Electrical law defines the relation between charge ("Positive" & "Negative") and electric field.  The law was initially formulated by Carl Friedrich Gauss in 1835.

In Gauss'... read more..


Introduction to Current Transformers

By Steven McFadyen on 2/8/2013 11:17 AM

Current transformers (CTs) are used to convert high level currents to a sma... read more..


Dielectric loss in cables

By Steven McFadyen on 11/12/2013 5:19 AM

Dielectrics (insulating materials for example) when subjected to a varying electric field, will have some energy loss.   The varying electric field causes small realignment of weakly bonded mo... read more..


What happened to the cable notes?

By Steven McFadyen on 8/5/2017 3:00 PM

If you are wondering what happe... read more..


Cable Sizing Software

By Steven McFadyen on 10/21/2016 12:31 PM

When sizing cables nearly, everyone uses some form of software. This ranges from homespun spreadsheets to complex network analyses software. Each has its advantages and disadvantages. read more..


Three Phase Current - Simple Calculation

By Steven McFadyen on 3/1/2009 11:47 AM

The calculation of current in a three phase system has been brought up on our site feedback and is a discussion I seem to get involved in every now and again. While some colleagues prefer to remember... read more..


Motor Efficiency Classification

By Steven McFadyen on 3/28/2012 2:05 PM

Electric motors are one of the most widely used items of electrical equipment. Improving motor efficiency benefits include, reduced power demand, lower operating costs and reduced environment impact.... read more..


Maximum Demand for Buildings

By Steven McFadyen on 6/16/2010 5:42 PM

Estimating maximum demand is a topic frequently discussed. Working out how much power to allow for a building can be very subjective . Allowing too much power results in additional equipment, increased ... read more..


Cable Sheath and Armour Loss

By Steven McFadyen on 10/13/2013 11:44 PM

When sizing cables, the heat generated  by losses within any sheath or armour need to be evaluated. When significant, it becomes a factor to be considered in the sizing of cables.

This ... read more..


Batteries

By Steven McFadyen on 4/8/2012 1:38 PM

A battery consists of one or more cells, each of which use stored chemical energy to produce electrical energy, There are many types of cells and these are combined in a multitude of ways to produce ... read more..


Pages: Prev1234567...16NextReturn Top


Software Usage Guidelines

Using software in our  work is essential for most of us and we are becoming even more dependant on it's use.  While software is a great asset, many times...

DC Component of Asymmetrical Faults

The image (reproduced from IEC 60909) shows a typical fault in an ac system.  From the illustration it can seen that there is an initial dc component ...

Three Phase Power Simplified

A single phase system is perhaps the most common type of system most people are familiar with. This is what people have in their homes and what appliances...

Paths of Flight

GE have put together a time-lapse video shown flight take-off and landings at some airports. An interesting view:

Restricted Earth Fault Protection

The windings of many medium and small sized transformers are protected by restricted earth fault (REF) systems. The illustration shows the principal of...

Operational Amplifier

The fundamental component of any analogue computer is the operational amplifier, or op amp. An operational amplifier (often called an op-amp,) is a high...

Hazardous Areas – IEC and NEC/CEC Comparison

Depending where in the world you work, you are likely following one of two standards International Electrotechnical Commission (IEC) National...

What is Aircraft Ground Power

Ever wondered what kind of power an aircraft uses when parked at the airport stand. Normally the aircraft generates it own power, but when parked with...

Aluminium Windings - Dry Type Transformers

The other day I was talking to a colleague who is a building services consultant.  Despite regularly specifying dry-type/cast resin transformers he was...

Power Factor

Power factor is the ratio between the real power (P in kW) and apparent power (S in kVA) drawn by an electrical load. The reactive power (Q in kVAr)...

Have some knowledge to share

If you have some expert knowledge or experience, why not consider sharing this with our community.  

By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.

To get started and understand our policy, you can read our How to Write an Electrical Note