Fault Calculation - Symmetrical Components

By Steven McFadyen on 3/27/2013 12:52 PM

For unbalance conditions the calculation of fault currents is more complex. One method of dealing with this is symmetrical components. Using symmetrical components, the unbalance system is broken dow... read more..


Hazardous Areas – IEC and NEC/CEC Comparison

By Steven McFadyen on 3/9/2012 11:39 AM

Depending where in the world you work, you are likely following one of two standards

  • International Electrotechnical Commissio... read more..


Maxwell's Equations - Gauss's Electric Field Law

By Steven McFadyen on 9/4/2013 3:47 PM

Gauss's Electrical law defines the relation between charge ("Positive" & "Negative") and electric field.  The law was initially formulated by Carl Friedrich Gauss in 1835.

In Gauss'... read more..


Introduction to Current Transformers

By Steven McFadyen on 2/8/2013 11:17 AM

Current transformers (CTs) are used to convert high level currents to a sma... read more..


Dielectric loss in cables

By Steven McFadyen on 11/12/2013 5:19 AM

Dielectrics (insulating materials for example) when subjected to a varying electric field, will have some energy loss.   The varying electric field causes small realignment of weakly bonded mo... read more..


What happened to the cable notes?

By Steven McFadyen on 8/5/2017 3:00 PM

If you are wondering what happe... read more..


Cable Sizing Software

By Steven McFadyen on 10/21/2016 12:31 PM

When sizing cables nearly, everyone uses some form of software. This ranges from homespun spreadsheets to complex network analyses software. Each has its advantages and disadvantages. read more..


Three Phase Current - Simple Calculation

By Steven McFadyen on 3/1/2009 11:47 AM

The calculation of current in a three phase system has been brought up on our site feedback and is a discussion I seem to get involved in every now and again. While some colleagues prefer to remember... read more..


Motor Efficiency Classification

By Steven McFadyen on 3/28/2012 2:05 PM

Electric motors are one of the most widely used items of electrical equipment. Improving motor efficiency benefits include, reduced power demand, lower operating costs and reduced environment impact.... read more..


Maximum Demand for Buildings

By Steven McFadyen on 6/16/2010 5:42 PM

Estimating maximum demand is a topic frequently discussed. Working out how much power to allow for a building can be very subjective . Allowing too much power results in additional equipment, increased ... read more..


Cable Sheath and Armour Loss

By Steven McFadyen on 10/13/2013 11:44 PM

When sizing cables, the heat generated  by losses within any sheath or armour need to be evaluated. When significant, it becomes a factor to be considered in the sizing of cables.

This ... read more..


Batteries

By Steven McFadyen on 4/8/2012 1:38 PM

A battery consists of one or more cells, each of which use stored chemical energy to produce electrical energy, There are many types of cells and these are combined in a multitude of ways to produce ... read more..


Pages: Prev1234567...16NextReturn Top


Power Factor

Power factor is the ratio between the real power (P in kW) and apparent power (S in kVA) drawn by an electrical load. The reactive power (Q in kVAr)...

Electrical Engineering

Electrical engineering is a field that covers a wide variety of sub-fields, including electricity and electronics. It is a field that goes back to the...

Cold Fusion (or not?)

Recently I have seen a few interesting articles on viable cold fusion; the combining of atoms at room like temperatures to create boundless energy. Now...

How to Calculate Motor Starting Time

Request to look at induction motor starting time have come up a few times on the site. Hopefully in this post, I give you guys some idea on how to calculate...

Cable Sheath and Armour Loss

When sizing cables, the heat generated  by losses within any sheath or armour need to be evaluated. When significant, it becomes a factor to be considered...

Paternoster Lifts

These lifts were first built in 1884 by J. E. Hall and called a paternoster ("Our Father", the first two words of the Lord's Prayer in Latin) due to its...

Occam's Razor

I was reminded of Occam's Razor while reading a book. It's quite a simple principal of logic which has stood the test of time and is accepted as central...

Voltage Drop in Installations - Concepts

Problems on achieving maximum voltage drop within an installation come up often. Depending where you live, local regulations will have different limits...

Generation of a Sine Wave

A fundamental concept behind the operation of alternating current systems is that voltage and current waveforms will be sinusoidal – a Sine Wave. This...

Photovoltaic (PV) - Utility Power Grid Interface

Photovoltaic (PV) systems are typically more efficient when connected in parallel with a main power gird. During periods when the PV system generates energy...