From the category archives: Buildings Technology

Electrical and related buildings technology

8 Motor parts and common faults

By Steven McFadyen on 12/6/2011 6:07 AM

Straight forward list of some common motor faults.  If I have missed any other common faults, please take a bit of time to add them in as a comment below. read more..


How to Calculate Motor Starting Time

By Steven McFadyen on 11/15/2011 2:00 PM

Request to look at induction motor starting time have come up a few times on the site. Hopefully in this post, I give you guys some idea on how to calculate this. Failing that, hopefully at least som... read more..


Voltage Drop in Installations - Concepts

By Steven McFadyen on 9/27/2011 7:50 AM

Problems on achieving maximum voltage drop within an installation come up often. Depending where you live, local regulations will have different limits on maximum allowable voltage drop, however the int... read more..


8 Steps to Low Voltage Power Cable Selection and Sizing

By Steven McFadyen on 7/25/2011 2:48 AM

A recurring theme on our forums is cable sizing. Now many installations are unique and require special consideration. However, a lot of the time things are just repeated. When looking at low voltage pow... read more..


Maximum Demand for Buildings

By Steven McFadyen on 6/16/2010 5:42 PM

Estimating maximum demand is a topic frequently discussed. Working out how much power to allow for a building can be very subjective . Allowing too much power results in additional equipment, increased ... read more..


3 Phase Loads

By Steven McFadyen on 5/4/2010 12:56 AM

Three phase systems are derived from three separate windings, either connected in delta or star (wye). Each winding can be treated separately, leading to the idea that the load in each winding can be vi... read more..


LED Replacement Light Bulb

By Steven McFadyen on 4/13/2010 12:08 AM

The inventor of the first visible light-emitting diode makes history again this year as it begins to show customers a 40-watt replacement GE Energy Smart® LED bulb available later this year or early... read more..


Lightning Risk Assessment (IEC 62305)

By Steven McFadyen on 9/27/2009 11:18 PM

IEC 62305 'Protection against lightning' requires a risk assessment be carried out to determine the characteristics of any lightning protection system to be installed. There is a lot of hype about about... read more..


110 or 230 Volts

By Steven McFadyen on 8/2/2009 10:50 PM

I've been considering a blog on the 110 or 230 Volt issue for a while.  While browsing the Internet I came across a great summary by Borat over at  engineering.com.  He ... read more..


IEC 61439 - The Switchgear Standard

By Steven McFadyen on 7/1/2009 3:08 AM

The new standard IEC 61439 replaces the old 60439. Compared to the old standard, the new 61439 is a more clearly defined and takes into account the assembly of pre-tested designs. .

Some key... read more..


UPS Sizing - Rules of Thumb

By Steven McFadyen on 4/30/2009 12:56 AM

It wasn't so long ago I was telling someone that I don't use rules of thumb as most things are easily calculated anyhow.   As it turns out I last week I ended up using what can only be describ... read more..


Three Phase Current - Simple Calculation

By Steven McFadyen on 3/1/2009 11:47 AM

The calculation of current in a three phase system has been brought up on our site feedback and is a discussion I seem to get involved in every now and again. While some colleagues prefer to remember... read more..


Pages: Prev12NextReturn Top


Low Voltage Switchroom Design Guide

Low voltage (LV) switchrooms are common across all industries and one of the more common spatial requirements which need to be designed into a project...

Fault Calculations - Typical Equipment Parameters

A frequent problem in fault calculations is the obtaining of equipment parameters.  While it is always preferable to use the actual parameters of the equipment...

Random Numbers

Using laser optical pulses the random number generator utilizes the time between arrival of random photos to generate the numbers, ensuring true accuracy...

IEC 61439 Verification Methods

The (relatively new) switchgear and control gear standard, IEC 61439 'Low-voltage switchgear and controlgear assemblies' has three methods which can be...

Write your best report

Years ago I was told that you should always try to write the best report you can.  Many years later I still think on this as one of the better pieces of...

Lightning Protection and Earth Electrode Resistance

Most installations involve some form of lightning protection system which is connected to an earth electrode.  The function of the earth electrode is to...

IEC 60287 Current Capacity of Cables - Rated Current

In the previous note we looked at the approach taken by the standard to the sizing of cables and illustrated this with an example.  We then looked at one...

Contribute to myElectrcial

Have an opinion or something to say, want to ask or answer questions, share your knowledge then use our site to do it . As a community of people interested...

Electromechanical Relays

Electromechanical relays have been the traditional backbone of electrical protection systems.  While over recent years these have been replaced by microprocessor...

Voltage Levels to IEC 60038

The standard aims to consolidate AC and traction voltages within the industry and defines the following bands: band 1 - A.C. systems 100 V to 1...

Have some knowledge to share

If you have some expert knowledge or experience, why not consider sharing this with our community.  

By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.

To get started and understand our policy, you can read our How to Write an Electrical Note