Fault Calculation - Symmetrical Components

By Steven McFadyen on 3/27/2013 12:52 PM

For unbalance conditions the calculation of fault currents is more complex. One method of dealing with this is symmetrical components. Using symmetrical components, the unbalance system is broken dow... read more..


Hazardous Areas – IEC and NEC/CEC Comparison

By Steven McFadyen on 3/9/2012 11:39 AM

Depending where in the world you work, you are likely following one of two standards

  • International Electrotechnical Commissio... read more..


Maxwell's Equations - Gauss's Electric Field Law

By Steven McFadyen on 9/4/2013 3:47 PM

Gauss's Electrical law defines the relation between charge ("Positive" & "Negative") and electric field.  The law was initially formulated by Carl Friedrich Gauss in 1835.

In Gauss'... read more..


Introduction to Current Transformers

By Steven McFadyen on 2/8/2013 11:17 AM

Current transformers (CTs) are used to convert high level currents to a sma... read more..


Dielectric loss in cables

By Steven McFadyen on 11/12/2013 5:19 AM

Dielectrics (insulating materials for example) when subjected to a varying electric field, will have some energy loss.   The varying electric field causes small realignment of weakly bonded mo... read more..


What happened to the cable notes?

By Steven McFadyen on 8/5/2017 3:00 PM

If you are wondering what happe... read more..


Cable Sizing Software

By Steven McFadyen on 10/21/2016 12:31 PM

When sizing cables nearly, everyone uses some form of software. This ranges from homespun spreadsheets to complex network analyses software. Each has its advantages and disadvantages. read more..


Three Phase Current - Simple Calculation

By Steven McFadyen on 3/1/2009 11:47 AM

The calculation of current in a three phase system has been brought up on our site feedback and is a discussion I seem to get involved in every now and again. While some colleagues prefer to remember... read more..


Motor Efficiency Classification

By Steven McFadyen on 3/28/2012 2:05 PM

Electric motors are one of the most widely used items of electrical equipment. Improving motor efficiency benefits include, reduced power demand, lower operating costs and reduced environment impact.... read more..


Maximum Demand for Buildings

By Steven McFadyen on 6/16/2010 5:42 PM

Estimating maximum demand is a topic frequently discussed. Working out how much power to allow for a building can be very subjective . Allowing too much power results in additional equipment, increased ... read more..


Cable Sheath and Armour Loss

By Steven McFadyen on 10/13/2013 11:44 PM

When sizing cables, the heat generated  by losses within any sheath or armour need to be evaluated. When significant, it becomes a factor to be considered in the sizing of cables.

This ... read more..


Batteries

By Steven McFadyen on 4/8/2012 1:38 PM

A battery consists of one or more cells, each of which use stored chemical energy to produce electrical energy, There are many types of cells and these are combined in a multitude of ways to produce ... read more..


Pages: Prev1234567...16NextReturn Top


Electromagnetic Compatibility (EMC)

Electromagnetic compatibility (EMC) is the study of coordinating electromagnetic fields give off equipment, with the withstand (compatibility) of other...

Capacitors - Energy Storage Application

Capacitors have numerous applications in electrical and electronic applications.  This note examines the use of capacitors to store electrical energy....

Inductance

When current flows within a wire, a magnetic field is created. The potion of this magnetic field perpendicular to the wire is called the magnetic flux...

Post Authorship

In 2011, with the introduction of it’s Panda search ranking algorithms, Google introduced tools for determining the original author of posts.  The intention...

Introduction to Current Transformers

Current transformers (CTs) are used to convert high level currents to a smaller more reasonable level for use as inputs to protection relays and metering...

Medium Voltage Switchgear Room Design Guide

Many medium voltage (MV) indoor switchgear rooms  exist worldwide. The complexity of these rooms varies considerably depending on location, function and...

MIT OpenCourseWare

MIT OpenCourseWare, makes the materials used in teaching all MIT subjects available on the Web, free of charge, to any user in the world.

How to Check a Circuit is Dead

If you want to check a circuit is dead (not live), you should always use the three point method. First check a known live circuit, then check the dead...

IEC 60287 Current Capacity of Cables - Rated Current

In the previous note we looked at the approach taken by the standard to the sizing of cables and illustrated this with an example.  We then looked at one...

Tip – Latitude and Longitude on Large Scale Plans

If you are working on a large plan, get the real coordinates [latitude, longitude] for two or more points and add them to the drawing. That way you can...

Have some knowledge to share

If you have some expert knowledge or experience, why not consider sharing this with our community.  

By writing an electrical note, you will be educating our users and at the same time promoting your expertise within the engineering community.

To get started and understand our policy, you can read our How to Write an Electrical Note